Once the home of William Steinmeyer Co., wholesale and retail grocers, this imposing building was completed the year after the founder died. Based on a cash-only philosophy, Steinmeyer had build a huge business by sending order solicitors around Milwaukee one day and making deliveries the next day. In the new building his son-in-law, Emil Ott, and his brother, Charles, continued the reputation for quality, service, and reasonable price until national chains and automobiles forced them to close in 1940. The handsome Richardsonian Romanesque building was designed by architects Ferry & Clas and cost $50,000. The pressed red brick is trimmed with orange terra-cotta and wrought iron. The structure was enlarged in 1898.

 

Activity

IDDateTypeDescription
PBFS-17-007602017/08/16Permit
Plumbing-Fire Protection Permit.
COM-ALT-17-006482017/07/25Permit
Commercial Alteration Permit.
ASBP-17-000842017/07/13Permit
Asbestos Project.
PLB-17-012012017/03/24Permit
Building Plumbing Permit.
HVAC-GEN-16-004082016/11/03Permit
HVAC General Permit.
ELEC-16-008732016/11/03Permit
Electrical Permit.
PLB-16-004922016/10/26Permit
Building Plumbing Permit.
2342972016/05/20Recording Application
new recording application
120913712016/05/14Violation

~~Recording required
11694652016/02/05Permit
Fire Alarm-Alteration
11688252016/01/29Permit
Temporary Occupancy
11664912016/01/05Permit
Temporary Occupancy
11664292015/12/30Permit
Plumbing-Repair
11661072015/12/23Permit
Electrical-New
11646142015/12/11Permit
Distribution Sys(ductwork)
11634952015/11/24Permit
Occupancy
11629432015/11/19Permit
Alteration
11606552015/10/28Permit
Fire Suppression r
11536372015/08/13Permit
Electrical-Repair
11524312015/08/04Permit
Fire Suppression r
116004612015/07/22Violation
EXTERIOR
~~Correct exterior maintenance violations cited in the Facade Inspection Report submitted by RCL Engineering Group dated 06/09/15 and provide a second report by a professional when the required work is completed. .. / MCO 275-32-13-i-2 /
115946812015/07/18Violation
~~{B} NFPA 55. Chapter 13 Insulated Liquid Carbon Dioxide Systems. 13.2 Small Insulated Liquid Carbon Dioxide Indoor Systems. {N} 13.2.2 Rooms or areas where container systems are filled and used indoors or in enclosed outdoor locations shall be provided with a gas detection and alarm system that is capable of detecting and notifying the building occupants of a gas release that creates carbon dioxide vapor in excess of its PEL. 13.2.2.1 Activation of the gas detection system shall initiate an audible alarm within the room or area in which the system is installed. {B} Install a carbon dioxide detector with alarm. {N}.. / MCO 223 /SPS 341.10(4) /~~{B} NFPA 55. 7.8.3.4 Securing Compressed Gas Containers, Cylinders, and Tanks. {N} Compressed gas containers, cylinders, and tanks in use or in storage shall be secured to prevent them from falling or being knocked over by corralling them and securing them to a cart, framework, or fixed object by use of a restraint, unless otherwise permitted by 7.1.8.4.1 and 7.1.8.4.2. {B} SECURE CO2 VESSEL FROM FALLING {N}.. / MCO 223 /SPS 341.10(4) /
11505272015/07/16Permit
Alteration
114108812015/04/07Violation
~~Submit facade critical exam report
113099512015/02/06Violation
RECORDING INCORRECT, FOR THESE REASON(S):
11225582014/10/23Permit
Fire Suppression r
111509712014/10/23Violation
EXTERIOR
~~275-32-13-i-2 Correct exterior maintenance violations cited in Facade Critical Examination Report submitted by Capstone Engineering Group dated May 10, 2010 and provide a completion report in duplicate to the Department of Neighborhood Services by a Wisconsin registered professional architect or engineer when the required work has been completed. / 275-32-13-i-2 /
111212012014/10/23Violation
~~~~~~Perform dry standpipe 1hr hydrostatic test 200psi
107720712014/03/31Violation
FIRE PREVENTION
      Replace missing cover on electric junction box
      Right of entry for required fire inspection
      Secure pressurized cylinders
      Discontinue the use of illegal extension cords
      Test monitored fire alarm system annually
      2006 IFC 1404.7 Electrical. Temporary wiring for electrical power and lighting installations used in connection with the construction, alteration or demolition of buildings, structures, equipment or similar activities shall comply with the ICC Electrical Code. NEC 2008 Article 590.3 (D) Removal. Temporary wiring shall be removed immediately upon completion of construction or purpose for which the wiring was installed. Disconnect temporary wiring from sprinkler lines and disconnect from electrical panel in all areas including, but not limited to, vacant space on second floor and basement area.. / 214-3 /
INTERIOR
      Basement
            Secure all electrical conduits to ceiling
            Provide clearance to electrical panels
11013862014/02/13Permit
Fire Suppression r
IDDateDescriptionType